Condensate Drain Into Plumbing Vent
Condensate Drain Into Plumbing Vent. You will draw sewer gas into the air handler and then the gas will be forced into your house. The head of the garden hose needs to be connected.
The condensation may not produce enough moisture to keep the traps full during low or even moderate humidity. Condensate drain into the waste pipe. Use a liberal amount of sealant to secure the fitting over the top and.
This Lets The Sewage Air Enter Your Ac System.
If discharging into a plumbing vent in the attic there must be a wet trap as defined by water discharge sufficient to maintain a seal on the trap. Vent stacks have 2 main functions; It is important to remember that the connection must be made before (above) the trap.
Condensate Waste Shall Not Drain Over A.
They both say pretty much the same thing. The ipc allows what you describe and you are correct it will be considered a wet vent from the point at which the drain connects to the existing vent. The actual condensate drain has it's own inline trap to prevent the fan from sucking air from the attic.
Condensate Drain Into The Waste Pipe.
If you use 1 1/2 at that distance the waste line must be revented to shorten the distance to the vent to no less. If the furnace is a 80% furnace it makes no condensate thus the trap could go dry when in the heating mode and could allow sewer gas into the air stream and into the home. Imc 307.2.2 tells us that an a/c condensate drain inside diameter should not be smaller than 3/4″ and should not be smaller than the drain pan outlet.
An A/C Condensate Drain Inside Diameter Should Not Be Smaller Than 3/4″ And Should Not Be Smaller Than The Drain Pan Outlet Diameter.
You will want to cut the waste vent pipe at the location where your new drain line is going to enter. Leo, no vent pipe is needed, but there are other things that may be in the same vein. Use a liberal amount of sealant to secure the fitting over the top and.
If It Is Made On The Trap Arm—Which Is After The Trap, As In The Photo Above—Then The.
Terminating the condensate piping from an a/c system to the house drain piping under a sink is definitley allowed, but rarely done here in florida. Just bought a new old house and the air handler sits in the garage, on the slab. But, make sure the drain pipe is always lower than the air conditioning unit.